Enterprise Networking Solution
Installation Guide
Gigabit Unmanaged Switch
TL-SG1048/TL-SG1024
TL-SG1024D/TL-SG1016
TL-SG1016D/TL-SG1008
COPYRIGHT & TRADEMARKS
Specifications are subject to change without notice.
is a registered trademark
of TP-LINK TECHNOLOGIES CO., LTD. Other brands and product names are trademarks of their
respective holders.
No part of the specifications may be reproduced in any form or by any means or used to make
any derivative such as translation, transformation, or adaptation without permission from TP-LINK
TECHNOLOGIES CO., LTD. Copyright © 2012 TP-LINK TECHNOLOGIES CO., LTD. All rights reserved.
FCC STATEMENT
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
11 This device may not cause harmful interference.
21 This device must accept any interference received, including interference that may cause
undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
CE Mark Warning
This is a Class A product. In a domestic environment, this product may cause radio interference, in
which case the user may be required to take adequate measures.
Copyright & Trademarks
I
Related Document
This Installation Guide is also available in PDF on our website. To obtain the latest
documentation and product information, please visit the official website:
About this Installation Guide
This Installation Guide describes the hardware characteristics, installation methods
and the points that should be attended to during installation. This Installation
Guide is structured as follows:
Chapter 1 Introduction. This chapter describes the external components of
the Switch.
Chapter 2 Installation. This chapter illustrates how to install the Switch.
Chapter 3 Lightning Protection. This chapter illustrates how to prevent
lightning damage.
Chapter 4 Connection. This chapter illustrates how to do the physical connec-
tion of the Switch.
Appendix A Troubleshooting.
Appendix B Specifications.
Appendix C Technical Support.
Audience
This Installation Guide is for:
Network Engineer
Network Administrator
Conventions
Due to the similarity in structure of the Gigabit Unmanaged Switch series, in
this Installation Guide we take TL-SG1024 as an example to illustrate Chapter 2
Installation, Chapter 3 Lightning Protection and Chapter 4 Connection.
This Guide uses the specific formats to highlight special messages. The following
table lists the notice icons that are used throughout this guide.
Remind to be careful. A caution indicates a potential which may result in
device damage.
Remind to take notice. The note contains the helpful information for a
better use of the product.
II
Related Document
Contents
Chapter 1 Introduction ——————————— 01
1.1
1.2
1.3
Product Overview...................................................................01
Features......................................................................................01
Appearance...............................................................................02
Chapter 2 Installation ———————————— 05
2.1
2.2
2.3
2.4
Package Contents...................................................................05
Safety Precautions..................................................................05
Installation Tools......................................................................07
Product Installation................................................................08
Chapter 3 Lightning Protection ———————— 10
3.1
3.2
3.3
3.4
Cabling Reasonably................................................................10
Connect to Ground.................................................................12
Equipotential Bonding..........................................................13
Use Lightning Arrester..........................................................14
Chapter 4 Connection ——————————— 16
4.1
4.2
4.3
4.4
Ethernet Port ............................................................................16
Verify Installation ....................................................................16
Power On....................................................................................16
Initialization ..............................................................................17
Appendix A Troubleshooting ————————— 18
Appendix B Speciꢀcations——————————— 19
Appendix C Technical Support ————————— 20
Contents
III
Gigabit Unmanaged Switch
ChaCter C Introduction
C1C Product Overview
The Gigabit Unmanaged Switch provides you with a high-performance, low-cost, easy-
to-use, seamless and standard upgrade to boost your old network to 1000Mbps.
Increase the speed of your network server and backbone connections, making
Gigabit a reality. Power users in the home, office, workgroup, or creative production
environment can now move large, bandwidth-intensive files faster. Transfer graphics,
CGI, CAD, or multimedia files and other applications that have to move large files
across the network almost instantly.
The Gigabit Unmanaged Switch features a non-blocking switching architecture that
forwards and filters packets at full wire-speed for maximum throughput, MAC address
auto-learning and auto-aging, IEEE802.3x flow control for full-duplex mode and
backpressure for half-duplex mode. It is compatible with all 10Mbps, 100Mbps and
1000Mbps Ethernet devices because it is standard-based. It protects your existing
network investments while providing you with a straightforward migration path to
faster Gigabit speeds.
The Gigabit Unmanaged Switch is plug-and-play and no configuration is required.
Auto MDI/MDI-X cable detection on all ports eliminates the need for crossover cable
or Uplink port. Each port can be used as general port or Uplink port, and any port can
be simply plugged into a server, a hub, a router or a switch, using the straight cable
or crossover cable. Diagnostic LEDs which display link status and activity, allow you to
quickly detect and correct problems on the network.
C11 Features
•
Complies with IEEE802.3, IEEE802.3u, IEEE802.3ab standards
•
•
8/16/24/48 10/100/1000Mbps Auto-Sense RJ45 ports supporting Auto-MDI/MDIX
All ports Support Full/Half Duplex transfer mode for 10/100Mbps and Full Duplex
transfer mode for 1000Mbps
•
•
Supports IEEE802.3x flow control for full-duplex mode and backpressure for half-
duplex transfer mode
Non-blocking switching architecture that forwards and filters packets at full wire-
speed for maximum throughput
•
•
•
•
Supports MAC address auto-learning and auto-aging
LED indicators for monitoring power, link, speed and activity
Desktop and rack-mountable steel case
Internal power supply
Introduction
01
Gigabit Unmanaged Switch
C11 ACCearance
■
Front Panel
The front panel of TL-SG1048 is shown as the following figure.
LEDs
10/100/1000Mbps RJ45 Port
Figure 1-1 Front Panel of
TL-SG1048
The front panel of TL-SG1024 is shown as the following figure.
LEDs
10/100/1000Mbps RJ45 Port
Figure 1-2 Front Panel of
TL-SG1024
The front panel of TL-SG1024D is shown as the following figure.
LEDs
10/100/1000Mbps RJ45 Port
Figure 1-3 Front Panel of
TL-SG1024D
The front panel of TL-SG1016 is shown as the following figure.
LEDs
10/100/1000Mbps RJ45 Port
Figure 1-4 Front Panel of
TL-SG1016
The front panel of TL-SG1016D is shown as the following figure.
LEDs
10/100/1000Mbps RJ45 Port
Figure 1-5 Front Panel of
TL-SG1016D
Introduction
02
Gigabit Unmanaged Switch
The front panel of TL-SG1008 is shown as the following figure.
LEDs
10/100/1000Mbps RJ45 Port
Figure 1-6 Front Panel of
Indication
TL-SG1008
LEDs
LED
Status
On
The Switch is powered on
Power
Off
The Switch is powered off or power supply is abnormal
There is a device linked to the corresponding port but
not active
On
Link/Act
Flashing
Off
The corresponding port is transmitting or receiving data
There is no device linked to the corresponding port
A 1000Mbps device is connected to the corresponding
port
On
Off
1000Mbps
A 10/100Mbps device or no device is connected to the
corresponding port
Note: TL-SG1048 has no 1000Mbps LEDs while its Link/Act LEDs can
indicate port speed by flashing different colors (Green:1000Mbps,
Yellow:10/100Mbps1.
10/100/1000Mbps Port
Designed to connect to the device with a bandwidth of 10Mbps, 100Mbps or
1000Mbps. Each has a corresponding Link/Act LED and a 1000Mbps LED. TL-SG1048
has no 1000Mbps LEDs while its Link/Act LEDs can indicate port speed by flashing
different colors (Green:1000Mbps,Yellow:10/100Mbps1.
Rear Panel
The rear panel of TL-SG1048 is shown as the following figure.
Power Socket
Grounding Terminal
Figure 1-F Rear Panel
of TL-SG1048
The rear panel of TL-SG1024/TL-SG1016 is shown as the following figure.
Introduction
03
Gigabit Unmanaged Switch
Power Socket
Grounding Terminal
Figure 1-8 Rear Panel
of TL-SG1024/TL-SG1016
The rear panel of TL-SG1024D/TL-SG1016D is shown as the following figure.
Grounding Terminal
Power Socket
Figure 1-F Rear Panel
of TL-SG1024D/TL-SG1016D
The rear panel of TL-SG1008 is shown as the following figure.
Grounding Terminal
Power Socket
Figure 1-10 Rear Panel
of TL-SG1008
Power Socket
Connect the female connector of the power cord here, and the male connector to
the AC (Alternating Current1 power outlet. Please make sure the voltage of the
power supply meets the requirement of the input voltage.
Grounding Terminal
The Switch already comes with lightning protection mechanism. You can also ground
the Switch through the PE (Protecting Earth1 cable of AC cord or with Ground Cable.
For detailed information, please refer to Chapter 3 Lightning Protection.
Caution: Please use the provided power cord.
Introduction
04
Gigabit Unmanaged Switch
ChaCter 1 Installation
11C Package Contents
Make sure that the package contains the following items. If any of the listed items is
damaged or missing, please contact your distributor.
One Switch
One Power Cord
This Installation Guide
Two mounting brackets and the
fittings
111 Safety Precautions
To avoid any device damage and bodily injury caused by improper use, please observe
the following rules.
■
Safety Precautions
■
Keep the power off during the installation.
■
Wear an ESD-preventive wrist strap, and make sure that the wrist strap has a good
skin contact and is well grounded.
■
Use only the power cord provided with the Switch.
■
Make sure that the supply voltage matches the specifications indicated on the rear
panel of the Switch.
■
Ensure the vent hole is well ventilated and unblocked.
■
Do not open or remove the cover of the Switch.
■
Before cleaning the device, cut off the power supply. Do not clean it by the waterish
cloth, and never use any other liquid cleaning method.
Installation
05
Gigabit Unmanaged Switch
■
Site Requirements
Temperature/Humidity
ꢀꢁȭ
ꢁȭ
Please keep a proper temperature and humidity in the equipment room. Too high/low
humidity may lead to bad insulation, electricity leakage, mechanical property changes
and corrosions. Too high temperature may accelerate aging of the insulation materials
and can thus significantly shorten the service life of the device. For normal temperature
and humidity of the device, please check the following table.
Environment
Operating
Storage
Temperature
0℃ ~ 40℃
Humidity
10% ~ F0%RH Non-condensing
5% ~ F0%RH Non-condensing
-40℃ ~ F0℃
Clearness
The dust accumulated on the Switch can be absorbed by static electricity and result
in poor contact of metal contact points. Some measures have been taken for the
device to prevent static electricity, but too strong static electricity can cause deadly
damage to the electronic elements on the internal circuit board. To avoid the effect of
static electricity on the operation of the Switch, please attach much importance to the
following items:
■
Dust the device regularly, and keep the indoor air clean.
■
Keep the device well grounded and ensure static electricity has been transferred.
Electromagnetic Interference
Electronic elements including capacitance and inductance on the device can be affected
by external interferences, such as conducted emission by capacitance coupling,
inductance coupling, and impedance coupling. To decrease the interferences, please
make sure to take the following measures:
■
Use the power supply that can effectively filter interference from the power grid.
■
Keep the device far from high-frequency, strong-current devices, such as radio
transmitting station.
■
Use electromagnetic shielding when necessary.
Installation
06
Gigabit Unmanaged Switch
Lightening Protection
Extremely high voltage currents can be produced instantly when lightning occurs and the air
in the electric discharge path can be instantly heated up to 20,000℃. As this instant current
is strong enough to damage electronic devices, more effective lightning protection measures
should be taken.
■
Ensure the rack and device are well earthed.
■
Make sure the power socket has a good contact with the ground.
■
Keep a reasonable cabling system and avoid induced lightning.
■
Use the signal SPD (Surge Protective Device1 when wiring outdoor.
Note: For detailed lightning protection measures, please refer to Chapter 3
Lightning Protection.
Installation Site
ꢀꢁꢂS
When installing the device on a rack or a flat workbench, please note the following
items:
■
The rack or workbench is flat and stable, and sturdy enough to support the weight
of 5.5kg at least.
■
The rack or workbench has a good ventilation system. The equipment room is well
ventilated.
■
The rack is well grounded. Keep the power socket less than 1.5 meters away from
the device.
111 Installation Tools
■
■
■
Phillips screwdriver
ESD-preventive wrist wrap
Cables
Note: These tools are not provided with our product. If needed, please self purchase
them.
Installation
07
Gigabit Unmanaged Switch
112 Product Installation
■
Desktop Installation
To install the device on the desktop, please follow the steps:
1. Set the device on a flat surface strong enough to support the entire weight of the
device with all fittings.
2. Remove the adhesive backing papers from the rubber feet.
3. Turnover the device and attach the supplied rubber feet to the recessed areas on
the bottom at each corner of the device.
Feet
Bottom of the Device
Notch
Figure 2-1 Desktop Installation
■
Rack Installation
To install the device in an EIA standard-sized, 1F-inch rack, follow the instructions
described below:
1. Check the grounding and stability of the rack.
2. Secure the supplied rack-mounting brackets to each side of the device with supplied
screws, as illustrated in the following figure.
Rack-mounting Bracket
Screw
Figure 2-2 Bracket Installation
3. After the brackets are attached to the device, use suitable screws (not provided1 to
secure the brackets to the rack, as illustrated in the following figure.
Installation
08
Gigabit Unmanaged Switch
Rack
Figure 2-3 Rack Installation
Caution:
■
Please set 5~10cm gaps around the device for air circulation.
Please avoid any heavy thing placed on the device.
■
■
Please mount devices in sequence from the bottom to top of the rack and ensure a
certain clearance between devices for the purpose of heat dissipation.
09
Installation
Gigabit Unmanaged Switch
ChaCter 1 Lightning Protection
11C Cabling Reasonably
In the actual network environment, you may need cable outdoors and indoors, and
the requirements for cabling outdoors and indoors are different. A reasonable cabling
system can decrease the damage of induced lightning to devices.
Note: It's not recommended using Ethernet cables outdoors. When cabling outdoors,
please use a signal lightning arrester.
■
Requirements for Cabling Outdoors
■
Aerial cabling without safeguard is not allowed.
■
It’s not allowed cabling down the building to connect network devices in different
floors.
■
Outdoor cables should be buried and paved to the indoor through basement. A
piece of steel wire should be paved underground along the pipe and connected to
the lightning protection terminal of the building for shielding. Before connecting the
cable to the device, install a signal lightning arrester on the corresponding port.
■
When an aerial cable is set up, the cable should be through a metal pipe (15m long
at least1 before coming into the building. The two ends of this metal pipe should
be grounded. Before connecting the cable to the device, install a signal lightning
arrester on the corresponding port.
■
It’s not necessary to pave STP cables through pipes. The shielded layer of STP cable
should be well grounded. Before connecting the cable to the device, install a signal
lightning arrester on the corresponding port.
Lightning Protection
10
Gigabit Unmanaged Switch
■
Requirements for Cabling Indoors
When cabling indoors, keep a certain distance away from the devices that may cause
high-frequency interferences, such as down-conductor cable, powerline, power
transformer and electromotor.
■
The main cable should be paved in the metal raceway of the access shaft. When
cabling, keep the loop area formed by the cable itself as small as possible.
■
Requirements for the distance between Ethernet cable and other pipelines are
shown in the table.
Ethernet Cable
Other Pipelines
Min Parallel Net Length L
Min Parallel-overlapping
Net Height H (mm1
(mm1
Down-conductor
PE
1000
50
300
20
Service pipe
150
150
500
300
300
20
Compressed air pipe
Thermal pipe (not wrapped1
Thermal pipe (wrapped1
Gas pipe
20
500
300
20
The two diagrams below demonstrate parallel net length and parallel-overlapping net
height.
Note: The above minimum net length/height is required when metal raceway is not
used. If any requirements cannot be met, you can add a steel tube or metal raceway
for shielding.
■
Requirements for the distance between Ethernet cable and high-power electric
devices are in following tables.
Min Parallel
Length (mm1
Cable
Pave Way
Parallel cabling
130
<2kVA
powerline
One is in the grounded metal raceway or metal pipe
F0
The both are in the grounded metal raceway or metal
pipe
10
Lightning Protection
11
Gigabit Unmanaged Switch
Min Parallel
Length (mm1
Cable
Pave Way
Parallel cabling
300
2~5kVA
powerline
One is in the grounded metal raceway or metal pipe
150
80
The both are in the grounded metal raceway or metal
pipe
Parallel cabling
600
300
>5kVA
One is in the grounded metal raceway or metal pipe
powerline
The both are in the grounded metal raceway or metal
pipe
150
Device
Min Distance (m1
Switch case
1.00
Transformer room
Elevator tower
2.00
2.00
2.00
Air-conditioner room
111 Connect to Ground
Connecting the device to ground is to quickly release the lightning over-voltage and
over-current of the device, which is also a necessary measure to protect the body from
electric shock.
In different environments, the device may be grounded differently. The following
will instruct you to connect the device to the ground in two ways, connecting to the
grounding bar or connecting to the ground via the power cord. Please connect the
device to ground in the optimum way according to your specific operation environment.
■
Connecting to the Grounding Bar
If the device is installed in the Equipment Room, where a grounding bar is available,
you are recommended to connect the device to the grounding bar as shown in the
following figure.
Grounding T e rminal
Grounding Bar
Switch (Rear Panel)
Ground Cable
Figure 3-1 Connecting to the Grounding Bar
Lightning Protection
12
Gigabit Unmanaged Switch
Note: The grounding bar and the ground cable are not provided with our product. If
needed, please self purchase them.
■
Connecting to the Ground via the Power Supply
If the device is installed in the normal environment, the device can be grounded via the
PE (Protecting Earth1 cable of the AC power supply as shown in the following figure.
Figure 3-2 Connecting to the Ground
Note:
■
The figure is to illustrate the application and principle. The power plug you get from
the package and the socket in your situation will comply with the regulation in your
country, so they may differ from the figure above.
If you intend to connect the device to the ground via the PE (Protecting Earth1 cable
■
of AC power cord, please make sure the PE (Protecting Earth1 cable in the electrical
outlet is well grounded in advance.
111 EquiCotential Bonding
Equipotential Bonding is the practice of intentionally electrically connecting all earthed
systems to the same grounding grid or connecting the grounding grids of all the
earthed systems together through the ground or overground metal so as to create
an earthed equipotential zone. When lightning occurs, the high voltage produced by
lightning current in all systems will meanwhile exist in their ground cables, and thus
all ground cables have the same electrical potential and basically eliminate the electric
strikes between the systems.
The figure below illustrates how to practice equipotential bonding in a network.
Lightning Protection
13
Gigabit Unmanaged Switch
Grounding T e rminal
Ground Cable
Equipotential Bonding Cable
Grounding Bar
Figure 3-3 Equipotential Bonding
When equipotential bonding, please note that the cable should be copper wrapped
Kelly with its area being 6mm2 at least. The shorter cable the better, and use a
grounding bar to establish an equipotential bonding point.
Note: The equipotential bonding cable and ground cable are not provided with our
product. If needed, please self purchase it.
112 Use Lightning Arrester
Power lightning arrester and signal lightning arrester are used for lighting protection.
Power lightning arrester is used for limiting the voltage surge due to a lightning. If an
outdoor AC power cord should be directly connected to the device, please use a power
lightning arrester.
Note: Power lightning arrester is not provided with our product. If needed, please self
purchase it.
Lightning Protection
14
Gigabit Unmanaged Switch
Signal lightning arrester is used to protect RJ45 ports of the device from lightning.
When cabling outdoors, please install a signal lightning arrester before connecting the
cable to the device.
When purchasing or using a signal lightning arrester, please observe the following
rules:
■
The port rate of the signal lightning arrester should match the rate of the desired
port on the device. If it is not matched, this signal lighting arrester will not work.
Purchase a standard lightning arrester.
■
Install signal lightning arrester near the protected device and connect it to the
ground via a shorter ground cable.
Grounding T e rminal
Equipotential Bonding Cable
Device
Ethernet Cable
Signal Lightning Arrester
Figure 3-4 Equipotential Bonding
Note: Signal lightning arrester is not provided with our product. If needed, please self
purchase it.
15
Lightning Protection
Gigabit Unmanaged Switch
ChaCter 2 Connection
21C Ethernet Port
Connect a Ethernet port of the Switch to the computer by RJ45 cable as the following
figure shown.
RJ45 Port
RJ45 Cable
Figure 4-1 Connecting the RJ45 Port
211 Verify Installation
After completing the installation, please verify the following items:
■
There are 5~10cm of clearance around the sides of the device for ventilation and
the air flow is adequate.
■
The voltage of the power supply meets the requirement of the input voltage of the device.
■
The power socket, device and rack are well grounded.
■
The device is correctly connected to other network devices.
211 Power On
Plug in the negative connector of the provided power cord into the power socket of the
device, and the positive connector into a power outlet as the following figure shown.
Figure 4-2 Connecting to Power Supply
16
Connection
Gigabit Unmanaged Switch
Note: The figure is to illustrate the application and principle. The power plug you get
from the package and the socket in your situation will comply with the regulation in
your country, so they may differ from the figure above.
212 Initialization
After the device is powered on, it begins the Power-On Self-Test. A series of tests run
automatically to ensure the device functions properly. During this time, its LED indica-
tors will respond as follows:
■
All of the LED indicators will flash momentarily for one second, which represents a
resetting of the system.
■
The Power LED indicator will light up.
17
Connection
Gigabit Unmanaged Switch
ACCendix A Troubleshooting
QQQQ The Power LED is not lit
The Power LED should be lit up when the power system works normally. If
the Power LED worked abnormally, please check as follows:
1. Make sure that the power cable is connected properly, and the power
contact is normal.
2. Make sure the voltage of the power supply meets the requirement of the
input voltage of the Switch.
QQQQ The Link/Act LED is not lit when a device is connected to the
corresConding Cort
Please check as follows:
1. Make sure that the cable connectors are firmly plugged into the Switch
and the device.
2. Make sure the connected device is turned on and working well.
3. The cable must be less than 100 meters long(328 feet1.
18
Troubleshooting
Gigabit Unmanaged Switch
ACCendix B SCecifications
Item
Content
IEEE 802.3 10Base-T
Standards
IEEE 802.3u 100Base-TX
IEEE 802.3ab 1000Base-T
10Base-T: UTP/STP of Cat. 3 or above(maximum 100m1
100Base-TX: 2-pair UTP/STP of Cat. 5 or above(maximum
100m1
Transmission Medium
1000Base-T: 4-pair UTP/STP of Cat. 5 or above(maximum
100m1
Safety & Emissions
Transfer Method
FCC, CE
Store-and-Forward
MAC Address Learning Automatically learning, automatically aging
10Base-T: 14881pps/Port
Frame Forward Rate
100Base-Tx: 148810pps/Port
1000Base-T: 14880F5pps/Port
Power, Link/Act, 1000Mbps (TL-SG1048 has no 1000Mbps
LEDs1
LEDs
~
Operating Temperature 0℃ 40℃
~
Storage Temperature
Operating Humidity
Storage Humidity
-40℃ F0℃
~
10% F0%RH Non-condensing
~
5% F0%RH Non-condensing
19
Specifications
Gigabit Unmanaged Switch
ACCendix C Technical SuCCort
■
To download the latest Firmware, Driver, Utility and User Guide, please go to:
■
For all other technical support, please contact us by using the following details:
■
Global
Tel: +86 F55 26504400
E-mail: [email protected]
Service time: 24hrs, F days a week
Singapore
Tel: +65 628404F3
E-mail: [email protected]
Service time: 24hrs, F days a week
UK
Tel: +44 (01 845 14F 001F
E-mail: [email protected]
Service time: 24hrs, F days a week
USA/Canada
Australia & New Zealand
Malaysia
Toll Free: +1 866 225 813F
E-mail: [email protected]
Service time: 24hrs, F days a week
Tel: AU 1300 8F 5465 NZ 0800 8F 5465
E-mail: [email protected]
Service time: 24hrs, F days a week
Tel: 1300 88 8F5465 (1300 88TPLINK1
Email: [email protected]
Service time: 24hrs, F days a week
Turkey
Tel: 444 1F 25 (Turkish Service1
E-mail: [email protected]
Service time: F:00 AM to 6:00 PM, F days a week
Italy
Tel: +3F 02 66F8FFFF
E-mail: [email protected]
Service time: F:00 AM to 6:00 PM, Monday to Friday
Indonesia
Tel: (+62 1 021 625F 135
E-mail: [email protected]
Service time: Monday to Friday
F:00-12:00 ; 13:00-18:00
*Except public holidays
Germany/Austria
Tel: +4F 1805 8F5465 (German Service1/+4F 1805 TPLINK
E-mail: [email protected]
Fee: 0.14 EUR/min from the German fixed phone network and up to 0.42
EUR/min from mobile phone
Service time: Monday to Friday F:00 AM to 6:00 PM
GMT+ 1 or GMT+ 2 (Daylight Saving Time in Germany1
*Except bank holidays in Hesse
Switzerland
Tel: +41 (01848 800FF8 (German Service1
E-mail: [email protected]
Fee: 4-8 Rp/min, depending on rate of different time
Service time: Monday to Friday F:00 AM to 6:00 PM,
GMT+ 1 or GMT+ 2 (Daylight Saving Time1
20
Technical Support
Gigabit Unmanaged Switch
Russian Federation
Tel: 8 (4F51 223-55-60
8 (8001 250-55-60 (toll-free call from any RF region1
E-mail: [email protected]
Service time: From 10:00 to 18:00 (Moscow time1
*Except weekends and holidays in Russian Federation
Brazilian(Portuguese Service1
Toll Free: 0800-FF0-433F
E-mail: [email protected]
Service time: Monday to Saturday 08:00 AM to 08:00 PM
Ukrainian
Tel: +380 (441 5F0-51-14
E-mail: [email protected]
Service time: Monday to Friday 14:00 PM to 22:00 PM
21
Technical Support
|